LG oven code F9: what it means and how to fix it

Your LG range starts to preheat, beeps, then shows F9 before the oven gets hot. This page explains what that code means, what you can safely check first, and what a technician will test if the code comes back.

A person answers Mon-Fri 9am-5pm local time. Outside those hours, leave a message and a company near you calls back.

Answered by an independent appliance repair company that serves your area. Not a call center.

Straight answer

LG oven code F9 means the control didn't see the oven get past 150°F within five minutes of preheat, so it stops and shows a no heat fault. The most common cause called out for this fault is a failed relay board, though gas models very often turn out to have a weak bake igniter that still glows.

Check these first

Safe to do yourself. Unplug the appliance before you start.

  1. Clear the code once

    Press Clear/Off, then try Bake again. If the code was a one-time control error after a power blink, the oven may start normally.

  2. Do one power reset

    Turn the range off at the breaker or unplug it for 3 to 5 minutes, then power it back up. LG lists this reset as a way to clear stored charge in the control, but if F9 returns, treat it as a real heating fault.

  3. For a gas range, check the shutoff valve

    Make sure the gas valve handle is lined up with the pipe. If it's turned across the pipe, the oven burner won't get gas, even though the display and cooktop ignition may seem normal.

  4. Watch what happens at preheat

    On a gas oven, look through the window if possible: a weak igniter may glow for a long time without flame. On an electric oven, note whether the oven stays cold while the display acts normal, since that points toward the bake circuit rather than the keypad.

  5. Check the door and vent area

    Make sure the door closes flat and nothing is blocking the oven vent. A bad seal or blocked vent is less common than an igniter, element, sensor, or board fault, but it's easy to rule out without opening the range.

Worth knowing

Conditions that make this more likely

Boards fail earlier in hot rooms

Electronics are rated for room temperature. In a garage or an unconditioned laundry room in summer, a control board can sit well above that for hours a day. Before replacing a board, a good technician confirms the parts it controls test good, since a shorted pump or valve can take out a new board too.

Check both breakers

Electric dryers and ranges run on a double 240V breaker. If only one leg trips, the drum can spin or the display can light with no heat. Reset both halves before assuming the appliance has failed.

What a technician tests

Most likely part first. These are for a technician with a meter and the tech sheet, not a weekend project.

PartHow it's tested
Gas bake igniterCall for Bake and read igniter current with a clamp meter on one igniter lead. A weak igniter can glow orange but stay below the current needed to open the safety valve; the stated working range is at least 3 amps, often around 3.3 to 3.6 amps.
Relay board and relay connectorConfirm the board receives the bake command and switches power out to the bake igniter or element. A failed relay board may show a burnt relay, heat-marked connector, loose plug, or no switched output when the control is calling for heat.
Bake element or broil elementWith power disconnected, inspect the element for blisters, cracks, separated coil spots, or burned terminals at the oven wall. A technician then checks continuity through the element and checks for a short to chassis.
Oven temperature sensorMeasure the sensor at the plug or at CN31 pins 4 and 5 on the main PCB, depending on access. A normal reading given for this LG fault path is about 1.09kΩ at 25°C; an open, shorted, or far-off reading can make the control think the oven isn't heating correctly.
Thermostat or thermal fuseCheck the safety thermostat and thermal fuse for continuity with the range unplugged. A melted thermostat, heat-damaged body, or open fuse after an overheat event will keep the oven from heating and can lead to F9.

Don't see your symptom?

Describe it on the phone. The company on the other end works on these every day and will know what to ask.

Call to be connected(888) 280-5160

Common questions about appliance repair

Can I reset an LG oven code F9?

Yes. Press Clear/Off, then remove power for 3 to 5 minutes. If F9 comes back during preheat, the oven has a heat failure that needs testing.

Does F9 mean the control board is bad?

It can, especially if the relay board isn't sending power to the heat circuit. Still, a weak gas igniter or failed electric element can look the same from the control's point of view.

Why does my gas igniter glow but the oven never lights?

That is a classic weak igniter symptom. The igniter has to pull enough current before the safety valve opens, so a worn igniter can glow and still fail the bake cycle.

Is F9 different on gas and electric LG ranges?

The code means the same thing: the oven didn't pass the 150°F preheat check in time. The likely parts differ, with gas models often pointing to the bake igniter and electric models pointing more toward the relay board, element, or sensor.

Can I keep using the cooktop if the oven shows F9?

Usually the cooktop is a separate function, but stop using the oven until the fault is found. If you smell gas, turn the oven off, shut the gas valve if you can do so safely, and arrange service.

Still showing the problem after the checks?

Call and describe what you tried. You'll be connected with an independent repair company near you.

(888) 280-5160